PM-700 SERIES PLATING MONITOR
53
Select Parameter Number Description
64 Display Menu
65 Setup Menu
Thickness Units 191
K⊕
192
µinch
193 Micron
194
µg/cm
2
195 mg/cm
2
Time Units 100 Hours
101 Minutes
102 Seconds
Simulate Mode 34 On
35 Off
Measurement Mode * 109 Single
110 Alternating
111 Dual
Probe Swap * 78 Auto
79 Manual
Process Number 45 Process 1
46 Process 2
47 Process 3
48 Process 4
* This parameter is only available in the dual probe models.
To initiate an Upload parameter store output, the host computer would send the
following data stream:
Header
(2 bytes)
Instruction Code
(1 byte)
Message
Length
(1 byte)
Command
Code or
Message
Checksum
(1 byte)
FFh FEh 10h 1h 0h EEh